A crack stitching kit containing everything required to strap and stitch across cracks in wall. Conform to BS EN 845-1: 2013 and conditions for CE marking for the retrofit reinforcement of cracked brickwork. Tensile loads in excess of 8kN

-->
The Thor Helical Crack Stitching Kit contains everything needed to reconnect and strengthen cracked brickwork and fractured masonry. A series of durable stainless steel helical rods are discretely bonded into slots formed into mortar bed joints to stitch across cracks, spread tension loads and create a reinforced zone that inhibits progression of the crack.
Crack Stitching Kits contain:
This effective, reliable and durable brick stitching system provides resilience against further cracking with minimal cost and little disruption.
Components are supplied in sufficient quantities to make a minimum of 48 kits. The components can be packed individually in distributor-supplied ‘crack stitching kit’ boxes.
A crack stitching kit containing everything required to strap and stitch across cracks in wall. Conform to BS EN 845-1: 2013 and conditions for CE marking for the retrofit reinforcement of cracked brickwork. Tensile loads in excess of 8kN
International Manufacturer of Precision Engineered Helical Bars, Wall Ties & Fixings
The Thor Helical Crack Stitching Kit contains everything needed to reconnect and strengthen cracked brickwork and fractured masonry. A series of durable stainless steel helical rods are discretely bonded into slots formed into mortar bed joints to stitch across cracks, spread tension loads and create a reinforced zone that inhibits progression of the crack.
Crack Stitching Kits contain:
This effective, reliable and durable brick stitching system provides resilience against further cracking with minimal cost and little disruption.
Components are supplied in sufficient quantities to make a minimum of 48 kits. The components can be packed individually in distributor-supplied ‘crack stitching kit’ boxes.
A crack stitching kit containing everything required to strap and stitch across cracks in wall. Conform to BS EN 845-1: 2013 and conditions for CE marking for the retrofit reinforcement of cracked brickwork. Tensile loads in excess of 8kN
PRODUCT SPECIFICATION
Thor Helical crack stitching bars are available in AISI304 grade Austenitic Stainless Steel. AISI316 stainless bars are available on special request. The bars are supplied in the following standard sizes
BS EN 845-1:2013 National Annex NA states that the bars need to provide an equivalent performance to the prescriptive 30mm x 5mm lateral restraint straps and the tension straps should have a declared tensile load capacity of at least 8kN
TYPICAL PERFORMANCE LOADS 400mm bar-embedment length in WHO-60 Grout (taken from CE Mark Testing)
Bar Diameter | Bars per Joint | Tension Load |
---|---|---|
6mm | Single Bar | 8.39kN |
7mm | Single Bar | 9.75kN |
8mm | Single Bar | 11.06kN |
9mm | Single Bar | 11.50kN |
6mm | Double Bar | 16.00kN |
7mm | Double Bar | 17.65kN |
8mm | Double Bar | 17.65kN |
5mm | Triple Bar | 14.34kN |
Single bars bedded 20mm deep: Double bars placed 15 & 25mm deep: Triple bars buried 10, 20 & 30mm deep. Height of slot at least 3mm greater than diameter of crack stitching bars. Depth of slot 35-40mm. All bars bonded in WHO-60 polymer modified grout
TYPICAL MECHANICAL PROPERTIES OF THOR HELICAL PROFILED BARSDiameter | CSA (mm2) | 0.2% Proof Stress (N/mm2) | Ult Tensile Strength (N/mm2)* | Mean Tensile Capacity # |
---|---|---|---|---|
5mm | 6 | >880 | 1025 – 1225 | 7 kN |
6mm | 8 | >870 | 1025 – 1225 | 9 kN |
7mm | 10 | >880 | 1025 – 1225 | 11 kN |
8mm | 13 | >790 | 1025 – 1225 | 14 kN |
9mm | 16 | >850 | 1025 – 1225 | 17 kN |
* Ultimate Tensile Strength is measured within a calibrated tolerance of +/- 2% # Mean Tensile Capacity is an indicative value derived from CSA x Mean UTS
TYPICAL PROPERTIES – WHO-60 Grout
Physical Properties | Strength |
---|---|
Compressive Strength – 7 days | 35N/mm² |
Compressive – 28 days | 55N/mm² |
Tensile Strength – 28 days | 5N/mm² |
Flexural Strength – 28 days | 12N/mm² |
Young’s modulus (fully cured) | 13kN/mm² |
This video demonstrates the helical bars being used to create deep brick beams to span a window opening. The stainless steel helical reinforcing bars are bonded with WHO-60 polymer modified grout into cut slots cut into masonry. It offers a quick, simple and durable solution for strengthening and stabalising damaged masonry structures